Continuous Insulation System DIAMOND<>FURR® PAT.

Description

DIAMOND<>FURR® PAT.

Continuous Insulation System

Specifications
Diamond-Furr-Product-Page-P-1016.pdf

LATH ATTACHMENT SYSTEM

For decades the plaster industry has been plagued with moisture intrusion problems and the
associated liability resulting from the damage. Building paper has been relied upon to
eliminate failures in the building envelope, however current building codes require that metal lath is to be
attached every 6” inches. Not to mention This equates to 21 screw holes or 42 staple penetrations in every 10 ft stud
length of the WRB.

FIRST REAL SOLUTION

As shown above the patented Diamond-Furr® Lath Attachment System offers the first real solution to these moisture
intrusion problems by completely eliminating the penetrations at the termination points and also reducing
field penetrations by 55%! Opposite to old and outdated methods. Also check out videos below.

Continuous Insulation System

Above all the Diamond-Furr C.I. System is the ONLY complete lathing system with specific trims designed for
every common condition: Field Furring, Plaster Stops, Base of Wall Weep, Expansion Joints, Drip
Edges, Inside and Outside Corners, Window Surrounds, Recessed Windows, horizontal and vertical
backing for architectural trims, Residential Window Furring/Flashing and more.

DIAMOND-FURR Benefits Show The Following:

• Complete System: D-F the only complete trim system designed for the energy codes
requiring continuous rigid insulation when 7/8” cement plaster is applied.
• Zero Penetrations: In addition D-F eliminates 100% of the fastener penetrations through the final WRB
around windows, doors and all other termination points. Fastener penetrations reduce by over 55%! Fasteners become self-sealed.
•  In addition Superior Lath Embedment: D-F provides the only uninterrupted 3/8” furring. The lath never
comes in contact with the WRB and removes the potential for tears.

More DIAMOND-FURR Benefits:

• Further more eliminates Scratch Coat: D-F’s optimal furring allows the option to eliminate the cost
associated with applying a scratch coat as 3/4” of cement can be safely applied in one pass!
• Also Flexible Lath Attachment: D-F’s system incorporates tying on lath, which results in a more
flexible connection and less potential for cracking.
• One Step Install: D-F trims incorporate Flashing, Trim, Furring and Lath attachment in one step.
• Also Reduce Termination Point Build-up.  SAF petroleum products are not required at every
termination point allowing a true 7/8” plaster depth and reduces potential for cracking.
• Finally Minimizes Risk. When Diamond-Furr products are installed the risk of moisture intrusion is minimized.

Continuous Insulation System

Eliminating the scratch coat with Diamond-Furr

As shown above this solution provides spectacular results. We provide plenty of information, test results and also 3D models.

Also Check Out More Diamond<> Furr® Products Below

Diamond Furr TT-4 (1″ CI System),DIAMOND FURR: CONVEN. 7/8″ – OUTSIDE CORNER,